AFES Simulator (Relative)

The Alchemical Free Energy Simulator (AFES) uses the same SimulatorProject helper as the other simulators. Searching for projects, creating a simulator project (create_project()), checking status, and downloading results are described in MD Simulator (Solution, Membrane) (see Status And Downloads).

Free Energy Simulator

For Free Energy and Quick Free Energy references, the simulator helper detects the selection mode from the reference project.

Supported Free Energy simulator modes are:

  • AMBER Relative Binding: Select morphs.

  • GROMACS Relative Binding: Select morphs.

  • BLaDE Relative Binding: Select groups.

The first ligand force field is selected automatically when the reference contains one or more force fields. You can inspect or change it explicitly:

sim.list_available_ligand_force_fields()
sim.set_ligand_force_field("gaff_fast")

The following inspection methods are available:

  • list_available_ligand_force_fields(): For Free Energy references, returns the force-field keys stored in reference_options.selectedForceFields.

  • set_ligand_force_field(ligand_force_field): Returns str with the selected ligand force field key.

  • get_free_energy_profile(): Returns SimulatorFreeEnergyProfile with program, application, mode, selection kind, force fields, and defaults.

  • show_free_energy_profile(): Prints the profile and returns SimulatorFreeEnergyProfile.

  • get_free_energy_options(): Returns SimulatorFreeEnergyOptions with selectable items by ligand force field.

  • format_free_energy_options(): Returns str containing the formatted option summary.

  • show_free_energy_options(): Prints all selectable items and returns SimulatorFreeEnergyOptions.

  • list_available_free_energy_items(): Returns list[str] for morphs, or list[SimulatorFreeEnergyGroupOption] for BLaDE groups.

  • show_available_free_energy_items(): Prints selectable items with zero-based indices and returns the same value as list_available_free_energy_items().

AMBER/GROMACS Relative Binding

Relative-binding AMBER and GROMACS references select morphs. The displayed morph labels are one-based labels such as "1-2".

Example:

free_energy_ref_id = "completed-free-energy-rb-project-id"

sim = molcube.create_simulator_project()
assert sim.create_project(
   title="afes_rb",
   ref_id=free_energy_ref_id,
)

sim.show_free_energy_profile()
sim.show_available_free_energy_items()
sim.add_free_energy_selection([0, 1])
sim.show_free_energy_selection()

assert sim.run_simulation()

The following selection methods are available:

  • add_free_energy_selection(indices): Add items by displayed zero-based index. Returns list[str] for selected morphs, or list[int] for selected BLaDE group indices.

  • delete_free_energy_selection(indices): Remove items by displayed zero-based index. Returns list[str] for selected morphs, or list[int] for selected BLaDE group indices.

  • set_free_energy_selection(values): Replace the selection with explicit values. Returns list[str] for selected morphs, or list[int] for selected BLaDE group indices.

  • get_free_energy_selection(): Returns SimulatorFreeEnergySelectionState with selected values, selected force field, readiness, and missing inputs.

  • format_free_energy_selection(): Returns str containing the formatted selection summary.

  • show_free_energy_selection(): Prints the current selection and returns SimulatorFreeEnergySelectionState.

  • clear_free_energy_selection(): Clears the current selection and returns SimulatorFreeEnergySelectionState.

Morph core details are loaded automatically for AMBER/GROMACS relative-binding references. This data includes start/end ligand names, core atom indices, raw SVGs, and highlighted SVGs.

The following arguments are available for the show_morph_core_detail method:

  • morph (str | int): Display morph label such as "1-2", raw morph label, or zero-based list index.

  • ligand_force_field (str | None): Ligand force field to inspect. Defaults to the selected force field.

Example:

sim.show_morph_core_detail("1-2")
sim.show_morph_core_detail(0)

Run arguments

The following arguments are available for run_free_energy() and run_simulation() when using Free Energy references:

  • trials (int): Number of trials. (default: 1)

Return:

  • bool: True when the simulator project is submitted successfully.

BLaDE Relative Binding

BLaDE relative-binding references select ligand groups. Each group entry contains a groupIndex and ligand names.

Example:

blade_ref_id = "completed-blade-rb-project-id"

sim = molcube.create_simulator_project()
assert sim.create_project(
   title="blade_rb",
   ref_id=blade_ref_id,
)

sim.show_available_free_energy_items()
sim.add_free_energy_selection([0])

assert sim.run_simulation(trials=1)

You can inspect group data directly:

groups = sim.list_available_groups()
sim.set_free_energy_selection([groups[0]["groupIndex"]])

The following list methods are available:

  • list_available_morphs(ligand_force_field): Returns list[str] with display morph labels such as "1-2".

  • list_available_ligands(ligand_force_field): Returns list[str] with ligand file names.

  • list_available_groups(ligand_force_field=None): Returns list[SimulatorFreeEnergyGroupOption] with groupIndex and ligandNames.